Self-leveling floors consist of Part A diluted epoxy resin formulated with colorants and fine filler components such as silica flour. Part B amine curing agent and Part C courser fillers. A proper ratio of liquids (A&B) to Fillers (Part C) is 1 to 4 This makes for a flowable mix. A serrated trowel is used to spread the mixture and a spiked roller is used to accelerate de-aeration and avoid surface defects durina c:urina As a result self-levelina flnnrg he effinientlv annlipd I In several hundred square feet per day.
The cured floor is ready for exposure to traffic 24 hours after application. This is determined by temperature conditions and the right selection of curative. EC422 is a curative of choice for this application in 55 0 F plus situations. Cooler ambient temperatures would require a faster curative (EC423) be blended in to assure a 24 hour return of the floor to traffic.